| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00316 | DFC-00452 | DPM1052510067961 | NJAA11500343 | AMI | 1PH | Display Alarm | Terminal Cover | - | REPLACE METER | closed | medium | 2026-03-05 13:50:10 |
| 2 | DFG-00316 | DFC-00455 | DPM1052510067959 | NJAA11471636 | AMI | 1PH | Program Issue | Date & Time | cepat 2 jam | REPLACE METER | closed | medium | 2026-03-05 13:52:00 |
| 3 | DFG-00316 | DFC-00457 | DPM1052510068735 | NEQA6865424 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-03-05 17:33:06 |
| 4 | DFG-00316 | DFC-00458 | DPM1052510068638 | NJAA10108272 | AMI | 1PH | Display Alarm | Temper | - | REPLACE METER | closed | medium | 2026-03-05 17:33:34 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00315 | DFC-00451 | DPM1052510066984 | NJAA11479480 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-03-04 16:54:14 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00314 | DFC-00444 | DPM1052510066059 | NJAA11454293 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-03-04 08:11:34 |
| 2 | DFG-00314 | DFC-00446 | DPM1052510065834 | NJAA11469241 | AMI | 1PH | Others | - | fizikal defect | REPLACE MODULE COVER | closed | medium | 2026-03-04 08:13:06 |
| 3 | DFG-00314 | DFC-00447 | DPM1052510066510 | NJAA11454165 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-03-04 08:14:07 |
| 4 | DFG-00314 | DFC-00448 | DPM1052510066538 | NJAA11461196 | AMI | 1PH | Physical Damage | Button | terminal cover | REPLACE METER | closed | medium | 2026-03-04 08:14:54 |
| 5 | DFG-00314 | DFC-00450 | DPM1052510066268 | NJAA11470840 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-03-04 08:16:04 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00313 | DFC-00441 | DPM1052510065370 | NJAA11472476 | AMI | 1PH | Display Alarm | Battery | 0 | REPLACE BATTERY | closed | medium | 2026-03-03 08:17:28 |
| 2 | DFG-00313 | DFC-00443 | DPM1052510065128 | NJAA11467899 | AMI | 1PH | Display Alarm | Modul Cover | - | REPLACE METER | closed | medium | 2026-03-03 08:18:39 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00312 | DFC-00433 | DPM1052510064647 | NJAA11471911 | AMI | 1PH | Program Issue | Date & Time | Cepat 30 minit | REPLACE METER | closed | medium | 2026-02-28 15:21:32 |
| 2 | DFG-00312 | DFC-00434 | DPM1052510064513 | NJAA11464328 | AMI | 1PH | Display Alarm | Battery | - | REPLACE BATTERY | closed | medium | 2026-02-28 15:23:32 |
| 3 | DFG-00312 | DFC-00435 | DPM1052510064367 | NEQA6931682 | AMI | 1PH | Program Issue | Date & Time | Lambat 2 hari | REPLACE METER | closed | medium | 2026-02-28 15:24:09 |
| 4 | DFG-00312 | DFC-00436 | DPM1052510064142 | NEQA6936560 | AMI | 1PH | Others | - | EEP_ERR | REPLACE METER | closed | medium | 2026-02-28 15:24:57 |
| 5 | DFG-00312 | DFC-00438 | DPM1052510064012 | NEQA6936571 | AMI | 1PH | Display Alarm | Battery | 0 | REPLACE BATTERY | closed | medium | 2026-02-28 15:26:48 |
| 6 | DFG-00312 | DFC-00439 | DPM1052510064057 | NEQA6949810 | AMI | 1PH | Physical Damage | Scratch | - | PASS | closed | medium | 2026-02-28 15:27:14 |
| 7 | DFG-00312 | DFC-00440 | DPM1052510064204 | NEQA6952082 | AMI | 1PH | Others | - | TCM printing terbalik | - | closed | medium | 2026-02-28 15:27:58 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00311 | DFC-00430 | DPM1052510063123 | NEQA6938595 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPLACE BATTERY | closed | medium | 2026-02-28 15:16:20 |
| 2 | DFG-00311 | DFC-00432 | DPM1052510063130 | NEQA6941432 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2026-02-28 15:17:33 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00310 | DFC-00425 | DPM1052510062196 | NEQA6931873 | AMI | 1PH | Program Issue | Factory Setting | - | REPROGRAM | closed | medium | 2026-02-27 09:10:29 |
| 2 | DFG-00310 | DFC-00426 | DPM1052510062391 | NEQA6932940 | AMI | 1PH | Display Alarm | Battery | 0 | REPLACE BATTERY | closed | medium | 2026-02-27 09:11:06 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00309 | DFC-00421 | DPM1052510061718 | NEQA6936930 | AMI | 1PH | Display Alarm | Temper | - | REPLACE METER | closed | medium | 2026-02-26 08:50:10 |
| 2 | DFG-00309 | DFC-00422 | DPM1052510061341 | NEQA6950143 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2026-02-26 08:50:55 |
| 3 | DFG-00309 | DFC-00423 | DPM1052510061850 | NEQA6949510 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2026-02-26 08:51:35 |
| 4 | DFG-00309 | DFC-00424 | DPM1052510061893 | NEQA6945768 | AMI | 1PH | Program Issue | Date & Time | 8/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-26 08:52:17 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00308 | DFC-00417 | DPM1052510059936 | NJAA11472825 | AMI | 1PH | Program Issue | Date & Time | Cepat 30 minit | REPLACE METER | closed | medium | 2026-02-24 09:34:54 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00307 | DFC-00412 | DPM1052510059708 | NEQA6937868 | AMI | 1PH | Display Alarm | Temper | - | REPLACE METER | closed | medium | 2026-02-23 10:05:57 |
| 2 | DFG-00307 | DFC-00413 | DPM1052510059566 | NEQA6929813 | AMI | 1PH | Physical Damage | Nameplate | - | PASS | closed | medium | 2026-02-23 10:06:45 |
| 3 | DFG-00307 | DFC-00415 | DPM1052510059159 | NEQA6935113 | AMI | 1PH | Program Issue | Date & Time | 8/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-23 10:09:22 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00306 | DFC-00409 | DPM1052510058299 | NEQA6952317 | AMI | 1PH | Program Issue | Factory Setting | Verify KT | REPROGRAM | closed | medium | 2026-02-19 10:20:54 |
| 2 | DFG-00306 | DFC-00410 | DPM1052510058342 | NEQA6937022 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-02-19 10:21:31 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00305 | DFC-00406 | DPM1052510057814 | NEQA6946046 | AMI | 1PH | Program Issue | Date & Time | 14/2/2026 | REPLACE METER | closed | medium | 2026-02-12 18:07:54 |
| 2 | DFG-00305 | DFC-00407 | DPM1052510057973 | NEQA6950413 | AMI | 1PH | Program Issue | Date & Time | 8/11/2026 | REPLACE BATTERY | closed | medium | 2026-02-12 18:08:56 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00304 | DFC-00405 | DPM1052510057624 | NEQA6938618 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-02-12 11:30:23 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00303 | DFC-00396 | DPM1052510056509 | NEQA6946514 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-11 09:09:06 |
| 2 | DFG-00303 | DFC-00397 | DPM1052510056561 | NEQA6943072 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-11 09:09:48 |
| 3 | DFG-00303 | DFC-00398 | DPM1052510056622 | NEQA6945841 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | - | REPLACE METER | closed | medium | 2026-02-11 09:10:55 |
| 4 | DFG-00303 | DFC-00399 | DPM1052510057059 | NEQA6936944 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | * | REMOVE DIRT | closed | medium | 2026-02-11 09:11:34 |
| 5 | DFG-00303 | DFC-00400 | DPM1052510055831 | NEQA6932471 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-11 09:13:32 |
| 6 | DFG-00303 | DFC-00401 | DPM1052510055970 | NEQA6951865 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-11 09:14:29 |
| 7 | DFG-00303 | DFC-00402 | DPM1052510056195 | NEQA6843666 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-02-11 09:15:19 |
| 8 | DFG-00303 | DFC-00403 | DPM1052510054570 | NEQA6940336 | AMI | 1PH | Program Issue | Factory Setting | Battery voltage | REPLACE BATTERY | closed | medium | 2026-02-11 09:16:03 |
| 9 | DFG-00303 | DFC-00404 | DPM1052510055270 | NEQA6937045 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-02-11 09:16:44 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00302 | DFC-00390 | DPM1052510052746 | NEQA6944846 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2026-02-03 17:40:15 |
| 2 | DFG-00302 | DFC-00391 | DPM1052510052738 | NEQA6940962 | AMI | 1PH | Power Supply Issue | No power | meter tak hidup | REPLACE METER | closed | medium | 2026-02-03 17:41:06 |
| 3 | DFG-00302 | DFC-00392 | DPM1052510052533 | NEQA6935023 | AMI | 1PH | Program Issue | Date & Time | date (7/11/25 time (13;33 ) | REPLACE BATTERY | closed | medium | 2026-02-03 17:42:42 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00301 | DFC-00383 | DPM1052510051537 | NEQA6930446 | AMI | 1PH | Others | - | fizikal module cover | REPLACE MODULE COVER | closed | medium | 2026-01-30 08:49:38 |
| 2 | DFG-00301 | DFC-00384 | DPM1052510051877 | NEQA6935797 | AMI | 1PH | Physical Damage | Nameplate | Tak slot in | PASS | closed | medium | 2026-01-30 08:50:24 |
| 3 | DFG-00301 | DFC-00385 | DPM1052510052434 | NEQA6937639 | AMI | 1PH | Program Issue | Date & Time | date n time ( cepat 5 minit ) | SET DATE N TIME | closed | medium | 2026-02-03 17:27:39 |
| 4 | DFG-00301 | DFC-00386 | DPM1052510052236 | NEQA6944010 | AMI | 1PH | Others | - | ada benda asing | REMOVE DIRT | closed | medium | 2026-02-03 17:30:16 |
| 5 | DFG-00301 | DFC-00387 | DPM1052510052269 | NEQA6942119 | AMI | 1PH | Others | - | fizikal module cover | REPLACE MODULE COVER | closed | medium | 2026-02-03 17:35:32 |
| 6 | DFG-00301 | DFC-00388 | DPM1052510052420 | NEQA6938082 | AMI | 1PH | Others | - | fizikal module cover | REPLACE MODULE COVER | closed | medium | 2026-02-03 17:36:58 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00300 | DFC-00375 | DPM1052510050827 | NEQA6943002 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REMOVE DIRT | closed | medium | 2026-01-29 10:58:46 |
| 2 | DFG-00300 | DFC-00376 | DPM1052510051017 | NEQA6944924 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REMOVE DIRT | closed | medium | 2026-01-29 10:59:18 |
| 3 | DFG-00300 | DFC-00377 | DPM1052510051191 | NEQA6936820 | AMI | 1PH | Program Issue | Factory Setting | Disalbe optical | REPROGRAM | closed | medium | 2026-01-29 11:00:06 |
| 4 | DFG-00300 | DFC-00378 | DPM1052510051175 | NEQA6939531 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | REPROGRAM | closed | medium | 2026-01-29 11:00:57 |
| 5 | DFG-00300 | DFC-00380 | DPM1052510051280 | NEQA6944851 | AMI | 1PH | Program Issue | Date & Time | 7/11/2025 | REPLACE BATTERY | closed | medium | 2026-01-29 11:07:00 |
| 6 | DFG-00300 | DFC-00381 | DPM1052510051497 | NEQA6941530 | AMI | - | Others | - | fizikal module cover | REPLACE MODULE COVER | closed | medium | 2026-01-29 14:07:04 |
| 7 | DFG-00300 | DFC-00382 | DPM1052510051492 | NEQA6930494 | AMI | 1PH | Others | - | fizikal module cover | REPLACE MODULE COVER | closed | medium | 2026-01-29 14:07:43 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00299 | DFC-00370 | DPM1052510048106 | NJAA11461894 | AMI | 1PH | Display Alarm | Terminal Cover | 0 | REPLACE METER | closed | medium | 2026-01-23 11:40:02 |
| 2 | DFG-00299 | DFC-00371 | DPM1052510048869 | NJAA11467803 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | REPROGRAM | closed | medium | 2026-01-23 11:40:37 |
| 3 | DFG-00299 | DFC-00372 | DPM1052510049059 | NEQA6945839 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-01-23 11:41:06 |
| 4 | DFG-00299 | DFC-00373 | DPM1052510048666 | NJAA11456266 | AMI | 1PH | Program Issue | Date & Time | 3/11/2025 | REPLACE BATTERY | closed | medium | 2026-01-23 11:42:05 |
| 5 | DFG-00299 | DFC-00374 | DPM1052510048944 | NJAA11461716 | AMI | 1PH | Program Issue | Date & Time | Cepat 2 jam 54 minit | REPLACE METER | closed | medium | 2026-01-23 11:43:09 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00298 | DFC-00367 | DPM1052510046249 | NJAA11451767 | AMI | 1PH | Program Issue | Date & Time | cepat 40 minit | REPLACE METER | closed | medium | 2026-01-14 15:23:40 |
| 2 | DFG-00298 | DFC-00368 | DPM1052510046461 | NJAA11465436 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | REPROGRAM | closed | medium | 2026-01-14 15:24:10 |
| 3 | DFG-00298 | DFC-00369 | DPM1052510046465 | NJAA11455592 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | REPROGRAM | closed | medium | 2026-01-14 15:24:46 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00297 | DFC-00365 | DPM1052510046033 | NJAA11466943 | AMI | 1PH | Others | - | Printing tcm terbalik | - | open | medium | 2026-01-14 10:04:03 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00296 | DFC-00364 | DPM1052510044688 | NJAA11468468 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-01-13 09:20:15 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00295 | DFC-00357 | DPM1052510044222 | NEQA6946194 | AMI | 1PH | Display Alarm | Battery | 0 | REPLACE BATTERY | closed | medium | 2026-01-12 10:02:50 |
| 2 | DFG-00295 | DFC-00358 | DPM1052510044260 | NJAA11454077 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-01-12 10:03:30 |
| 3 | DFG-00295 | DFC-00359 | DPM1052510043902 | NJAA11461832 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-01-12 10:03:49 |
| 4 | DFG-00295 | DFC-00360 | DPM1052510043744 | NEQA6931081 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | REPROGRAM | closed | medium | 2026-01-12 10:04:16 |
| 5 | DFG-00295 | DFC-00361 | DPM1052510043529 | NEQA6939177 | AMI | 1PH | Display Alarm | Terminal Cover | 0 | REPLACE METER | closed | medium | 2026-01-12 10:04:53 |
| 6 | DFG-00295 | DFC-00362 | DPM1052510043403 | NJAA11457386 | AMI | 1PH | Program Issue | Date & Time | Cepat 10 minit | REPLACE METER | closed | medium | 2026-01-12 10:05:42 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00294 | DFC-00345 | DPM1052510042546 | NJAA11466404 | AMI | 1PH | Program Issue | Factory Setting | set date and time | REPROGRAM | closed | medium | 2026-01-08 17:36:31 |
| 2 | DFG-00294 | DFC-00346 | DPM1052510042490 | NJAA11457228 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2026-01-08 17:37:09 |
| 3 | DFG-00294 | DFC-00347 | DPM1052510042371 | NJAA11451934 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2026-01-08 17:37:36 |
| 4 | DFG-00294 | DFC-00349 | DPM1052510042426 | NJAA11468410 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2026-01-08 17:38:31 |
| 5 | DFG-00294 | DFC-00350 | DPM1052510042015 | NJAA11465242 | AMI | 1PH | Physical Damage | Button | 0 | remove dirt at button | closed | medium | 2026-01-08 17:39:13 |
| 6 | DFG-00294 | DFC-00351 | DPM1052510042515 | NJAA11458672 | AMI | 1PH | Physical Damage | Button | 0 | REMOVE DIRT AT BUTTON | closed | medium | 2026-01-08 17:39:39 |
| 7 | DFG-00294 | DFC-00352 | DPM1052510042295 | NJAA11458138 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPLACE BATTERY | closed | medium | 2026-01-08 17:40:34 |
| 8 | DFG-00294 | DFC-00353 | DPM1052510042369 | NJAA11451957 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REPLACE METER | closed | medium | 2026-01-08 17:40:59 |
| 9 | DFG-00294 | DFC-00354 | DPM1052510043041 | NJAA11481078 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2026-01-09 10:15:38 |
| 10 | DFG-00294 | DFC-00355 | DPM1052510041755 | NJAA11470789 | AMI | 1PH | Program Issue | Date & Time | cepat 1 hari | REPLACE METER | closed | medium | 2026-01-09 10:16:27 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00293 | DFC-00340 | DPM1052510040784 | NJAA11456320 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2026-01-08 12:54:42 |
| 2 | DFG-00293 | DFC-00342 | DPM1052510040876 | NJAA11470831 | AMI | 1PH | Program Issue | Factory Setting | verify battery voltage | PASS | closed | medium | 2026-01-08 12:56:28 |
| 3 | DFG-00293 | DFC-00343 | DPM1052510040811 | NJAA11461144 | AMI | 1PH | Program Issue | Date & Time | lambat 1 jam | REPLACE METER | closed | medium | 2026-01-08 14:05:00 |
| 4 | DFG-00293 | DFC-00344 | DPM1052510041254 | NJAA11454973 | AMI | 1PH | Program Issue | Date & Time | 31/10/2025 | SET DATE N TIME | closed | medium | 2026-01-08 14:05:43 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00292 | DFC-00337 | DPM1052510039228 | NJAA11508118 | AMI | 1PH | Display Alarm | Battery | verify batery voltage | REPROGRAM | closed | medium | 2026-01-07 09:30:15 |
| 2 | DFG-00292 | DFC-00338 | DPM1052510039368 | NJAA11462833 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2026-01-07 09:31:37 |
| 3 | DFG-00292 | DFC-00339 | DPM1052510040570 | NJAA11468964 | AMI | 1PH | Program Issue | Factory Setting | clear event | REPROGRAM | closed | medium | 2026-01-07 09:32:54 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00291 | DFC-00328 | DPM1052510038125 | NJAA11465899 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPROGRAM | closed | medium | 2025-12-31 17:44:53 |
| 2 | DFG-00291 | DFC-00329 | DPM1052510038170 | NJAA11489668 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:45:31 |
| 3 | DFG-00291 | DFC-00330 | DPM1052510038815 | NJAA11465972 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:46:05 |
| 4 | DFG-00291 | DFC-00331 | DPM1052510038938 | NJAA11508467 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-12-31 17:46:50 |
| 5 | DFG-00291 | DFC-00332 | DPM1052510039062 | NJAA11507761 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-12-31 17:47:28 |
| 6 | DFG-00291 | DFC-00333 | DPM1052510037816 | NJAA11471098 | AMI | 1PH | Display Alarm | Battery | battery voltage | REPROGRAM | closed | medium | 2025-12-31 17:48:13 |
| 7 | DFG-00291 | DFC-00334 | DPM1052510037948 | NJAA11454360 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-31 17:48:48 |
| 8 | DFG-00291 | DFC-00335 | DPM1052510038057 | NJAA11465671 | AMI | 1PH | Display Alarm | Battery | battery voltage | REPLACE BATTERY | closed | medium | 2025-12-31 17:49:42 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00290 | DFC-00320 | DPM1052510036156 | NJAA11470981 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPROGRAM | closed | medium | 2025-12-31 17:36:40 |
| 2 | DFG-00290 | DFC-00321 | DPM1052510036169 | NJAA11471018 | AMI | 1PH | Program Issue | Factory Setting | disable optical | REPROGRAM | closed | medium | 2025-12-31 17:38:09 |
| 3 | DFG-00290 | DFC-00322 | DPM1052510036285 | NJAA11474158 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPROGRAM | closed | medium | 2025-12-31 17:38:55 |
| 4 | DFG-00290 | DFC-00323 | DPM1052510036455 | NJAA11466962 | AMI | 1PH | Physical Damage | Button | button stuck | REMOVE DIRT AT BUTTON | closed | medium | 2025-12-31 17:40:04 |
| 5 | DFG-00290 | DFC-00324 | DPM1052510037539 | NJAA11452858 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:41:13 |
| 6 | DFG-00290 | DFC-00325 | DPM1052510037258 | NJAA11455962 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:41:45 |
| 7 | DFG-00290 | DFC-00326 | DPM1052510036986 | NJAA11453758 | AMI | 1PH | Program Issue | Factory Setting | clear event/energy | REPROGRAM | closed | medium | 2025-12-31 17:42:38 |
| 8 | DFG-00290 | DFC-00327 | DPM1052510037670 | NJAA11490022 | AMI | 1PH | Program Issue | Factory Setting | clear event/energy | REPROGRAM | closed | medium | 2025-12-31 17:43:49 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00289 | DFC-00259 | DPM1052510032735 | NJAA11452278 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-29 16:21:52 |
| 2 | DFG-00289 | DFC-00316 | DPM1052510035671 | NJAA11468225 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:30:50 |
| 3 | DFG-00289 | DFC-00317 | DPM1052510035897 | NJAA11454604 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-12-31 17:33:40 |
| 4 | DFG-00289 | DFC-00318 | DPM1052510035887 | NJAA11451762 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-31 17:34:25 |
| 5 | DFG-00289 | DFC-00319 | DPM1052510036044 | NJAA11472507 | AMI | 1PH | Display Alarm | Battery | verify battery voltage | REPROGRAM | closed | medium | 2025-12-31 17:35:45 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00288 | DFC-00309 | DPM1052510035124 | NJAA11468738 | AMI | 1PH | Program Issue | Factory Setting | disable optical | REPROGRAM | closed | medium | 2025-12-31 17:21:56 |
| 2 | DFG-00288 | DFC-00310 | DPM1052510035257 | NJAA11453084 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-31 17:23:48 |
| 3 | DFG-00288 | DFC-00311 | DPM1052510035258 | NJAA11467809 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-31 17:24:39 |
| 4 | DFG-00288 | DFC-00312 | DPM1052510035244 | NJAA11459109 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-31 17:25:21 |
| 5 | DFG-00288 | DFC-00313 | DPM1052510035477 | NJAA11469125 | AMI | 1PH | Program Issue | Factory Setting | shakehand | REPROGRAM | closed | medium | 2025-12-31 17:25:59 |
| 6 | DFG-00288 | DFC-00314 | DPM1052510035478 | NJAA11467832 | AMI | 1PH | Program Issue | Factory Setting | shakehand | REPLACE METER | closed | medium | 2025-12-31 17:28:42 |
| 7 | DFG-00288 | DFC-00315 | DPM1052510035521 | NJAA11468850 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-31 17:29:35 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00287 | DFC-00293 | DPM1052510033174 | NJAA11456188 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:20:33 |
| 2 | DFG-00287 | DFC-00294 | DPM1052510033136 | NJAA11502003 | AMI | 1PH | Physical Damage | Missing Modul Thread | NO THREAD TERMINAL | INSERT THREAD | closed | medium | 2025-12-30 18:21:49 |
| 3 | DFG-00287 | DFC-00295 | DPM1052510033184 | NEQA6950359 | AMI | 1PH | Display Alarm | Temper | temper | REPLACE METER | closed | medium | 2025-12-30 18:22:47 |
| 4 | DFG-00287 | DFC-00296 | DPM1052510033611 | NJAA11460246 | AMI | 1PH | Program Issue | Factory Setting | merah factory setting | REDO FACTORY SETTING | closed | medium | 2025-12-30 18:23:20 |
| 5 | DFG-00287 | DFC-00297 | DPM1052510033421 | NJAA11507880 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:24:08 |
| 6 | DFG-00287 | DFC-00298 | DPM1052510033374 | NJAA11465596 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:24:48 |
| 7 | DFG-00287 | DFC-00299 | DPM1052510033283 | NJAA11458369 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:25:26 |
| 8 | DFG-00287 | DFC-00300 | DPM1052510033846 | NJAA11464082 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:26:16 |
| 9 | DFG-00287 | DFC-00301 | DPM1052510033797 | NJAA11465057 | AMI | 1PH | Program Issue | Factory Setting | merah factory setting | REPROGRAM | closed | medium | 2025-12-31 08:45:02 |
| 10 | DFG-00287 | DFC-00302 | DPM1052510033551 | NJAA11455798 | AMI | 1PH | Program Issue | Factory Setting | disable optical | REPROGRAM | closed | medium | 2025-12-31 08:45:45 |
| 11 | DFG-00287 | DFC-00303 | DPM1052510033566 | NJAA11460256 | AMI | 1PH | Program Issue | Factory Setting | disable optical | REPROGRAM | closed | medium | 2025-12-31 08:46:30 |
| 12 | DFG-00287 | DFC-00305 | DPM1052510033466 | NJAA11490204 | AMI | 1PH | Program Issue | Date & Time | awal 15 minit | REPLACE METER | closed | medium | 2025-12-31 08:48:50 |
| 13 | DFG-00287 | DFC-00307 | DPM1052510034453 | NJAA11467978 | AMI | 1PH | Program Issue | Factory Setting | disable optical | REPROGRAM | closed | medium | 2025-12-31 08:50:39 |
| 14 | DFG-00287 | DFC-00308 | DPM1052510034566 | NJAA11476865 | AMI | 1PH | Program Issue | Factory Setting | read register | REPROGRAM | closed | medium | 2025-12-31 17:20:18 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00286 | DFC-00285 | DPM1052510032277 | NJAA11471943 | AMI | 1PH | Program Issue | Factory Setting | read rated voltage | REPROGRAM | closed | medium | 2025-12-30 18:11:23 |
| 2 | DFG-00286 | DFC-00286 | DPM1052510032590 | NJAA11455384 | AMI | 1PH | Display Alarm | Battery | lambang battery | REPLACE BATTERY | closed | high | 2025-12-30 18:12:07 |
| 3 | DFG-00286 | DFC-00287 | DPM1052510032345 | NJAA11458774 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:12:50 |
| 4 | DFG-00286 | DFC-00288 | DPM1052510032823 | NJAA11502084 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:13:42 |
| 5 | DFG-00286 | DFC-00289 | DPM1052510032835 | NJAA11460396 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:14:23 |
| 6 | DFG-00286 | DFC-00290 | DPM1052510032877 | NJAA11507739 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:15:13 |
| 7 | DFG-00286 | DFC-00291 | DPM1052510033031 | NJAA11481229 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:15:43 |
| 8 | DFG-00286 | DFC-00292 | DPM1052510032892 | NJAA11455382 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:16:22 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00285 | DFC-00275 | DPM1052510031331 | NJAA11498237 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 17:59:44 |
| 2 | DFG-00285 | DFC-00276 | DPM1052510030405 | NJAA11482719 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:00:45 |
| 3 | DFG-00285 | DFC-00277 | DPM1052510030574 | NJAA11496938 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:01:36 |
| 4 | DFG-00285 | DFC-00278 | DPM1052510031002 | NJAA11480106 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:02:26 |
| 5 | DFG-00285 | DFC-00279 | DPM1052510031080 | NJAA11505227 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 18:03:04 |
| 6 | DFG-00285 | DFC-00280 | DPM1052510030988 | NJAA11499248 | AMI | 1PH | Physical Damage | Scratch | scratch | REPLACE METER | closed | medium | 2025-12-30 18:03:55 |
| 7 | DFG-00285 | DFC-00281 | DPM1052510031482 | NJAA11501129 | AMI | 1PH | Physical Damage | Scratch | scratch | PASS | closed | medium | 2025-12-30 18:04:27 |
| 8 | DFG-00285 | DFC-00282 | DPM1052510031516 | NJAA11459794 | AMI | 1PH | Program Issue | Date & Time | awal 12 jam | REPLACE METER | closed | medium | 2025-12-30 18:06:21 |
| 9 | DFG-00285 | DFC-00283 | DPM1052510031372 | NJAA11469061 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:07:18 |
| 10 | DFG-00285 | DFC-00284 | DPM1052510031972 | NJAA11502063 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-30 18:07:47 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00284 | DFC-00261 | DPM1052510028876 | NJAA11455732 | AMI | 1PH | Program Issue | Date & Time | time: 6.01 pm | REPLACE METER | closed | medium | 2025-12-30 09:56:37 |
| 2 | DFG-00284 | DFC-00262 | DPM1052510029363 | NJAA11460950 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTINGkt | REDO FACTORY SETTING | closed | medium | 2025-12-30 10:00:05 |
| 3 | DFG-00284 | DFC-00263 | DPM1052510029425 | NJAA11455449 | AMI | 1PH | Program Issue | Date & Time | cepat 1 jam 40 minit | SET DATE N TIME | closed | medium | 2025-12-30 10:03:04 |
| 4 | DFG-00284 | DFC-00264 | DPM1052510030365 | NJAA11475597 | AMI | 1PH | Display Alarm | Battery | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-30 17:29:35 |
| 5 | DFG-00284 | DFC-00265 | DPM1052510030163 | NJAA11462503 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 17:30:35 |
| 6 | DFG-00284 | DFC-00266 | DPM1052510030127 | NJAA11463105 | AMI | 1PH | Others | - | TCM TERBALIK | - | open | medium | 2025-12-30 17:31:38 |
| 7 | DFG-00284 | DFC-00267 | DPM1052510029959 | NJAA11461994 | AMI | 1PH | Program Issue | Date & Time | LAMBAT 2 minit | REPLACE METER | closed | medium | 2025-12-30 17:32:47 |
| 8 | DFG-00284 | DFC-00268 | DPM1052510029674 | NJAA11466446 | AMI | 1PH | Others | Date & Time | date= 28/10/25 masa = cepat 8 jam | REPLACE BATTERY | closed | medium | 2025-12-30 17:34:56 |
| 9 | DFG-00284 | DFC-00269 | DPM1052510029708 | NJAA11465410 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-12-30 17:36:54 |
| 10 | DFG-00284 | DFC-00270 | DPM1052510029736 | NJAA11460500 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 17:37:37 |
| 11 | DFG-00284 | DFC-00271 | DPM1052510029769 | NJAA11455279 | AMI | 1PH | Others | Date & Time | date = 28/10/25 masa = cepat 6 jam | REPLACE BATTERY | closed | medium | 2025-12-30 17:39:31 |
| 12 | DFG-00284 | DFC-00272 | DPM1052510030007 | NJAA11451625 | AMI | 1PH | Program Issue | Date & Time | cepat 1 jam | REPLACE METER | closed | medium | 2025-12-30 17:40:17 |
| 13 | DFG-00284 | DFC-00273 | DPM1052510030018 | NJAA11467008 | AMI | 1PH | Program Issue | Date & Time | lambat 2 minit | SET DATE N TIME | closed | medium | 2025-12-30 17:41:04 |
| 14 | DFG-00284 | DFC-00274 | DPM1052510030106 | NJAA11454514 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-30 17:42:05 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00283 | DFC-00243 | DPM1052510025991 | NJAA11464054 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-17 15:28:40 |
| 2 | DFG-00283 | DFC-00244 | Disable opticalM1052510025812 | NJAA11462011 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-17 15:29:13 |
| 3 | DFG-00283 | DFC-00245 | DPM1052510026682 | NJAA11453374 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-17 15:29:39 |
| 4 | DFG-00283 | DFC-00246 | DPM1052510026691 | NJAA11502068 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-17 15:30:09 |
| 5 | DFG-00283 | DFC-00247 | DPM1052510025057 | NEQA6950665 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-17 15:30:33 |
| 6 | DFG-00283 | DFC-00248 | DPM1052510028368 | NJAA11462298 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-17 19:32:22 |
| 7 | DFG-00283 | DFC-00249 | DPM1052510027321 | NJAA11463668 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-17 19:32:41 |
| 8 | DFG-00283 | DFC-00250 | DPM1052510028620 | NJAA11460175 | AMI | 1PH | Program Issue | Factory Setting | Battery voltage | REPLACE BATTERY | closed | medium | 2025-12-17 19:33:30 |
| 9 | DFG-00283 | DFC-00251 | DPM1052510026854 | NJAA11497886 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-17 19:34:22 |
| 10 | DFG-00283 | DFC-00252 | DPM1052510028336 | NJAA11467330 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-17 19:34:44 |
| 11 | DFG-00283 | DFC-00253 | DPM1052510028642 | NJAA11462698 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-17 19:35:20 |
| 12 | DFG-00283 | DFC-00254 | DPM1052510027572 | NJAA11455819 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-17 19:35:39 |
| 13 | DFG-00283 | DFC-00255 | DPM1052510028067 | NJAA11467138 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REPLACE METER | closed | medium | 2025-12-17 19:36:10 |
| 14 | DFG-00283 | DFC-00256 | DPM1052510027968 | NJAA11468866 | AMI | 1PH | Program Issue | Date & Time | Lambat 15 minit | REPLACE METER | closed | medium | 2025-12-17 19:37:19 |
| 15 | DFG-00283 | DFC-00257 | DPM1052510027282 | NJAA11463817 | AMI | 1PH | Program Issue | Date & Time | Cepat 2 jam | REPLACE METER | closed | medium | 2025-12-17 19:37:50 |
| 16 | DFG-00283 | DFC-00258 | DPM1052510028403 | NJAA11473102 | AMI | 1PH | Program Issue | Date & Time | 28/10/2025 | SET DATE N TIME | closed | medium | 2025-12-17 19:38:32 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00282 | DFC-00224 | DPM1052510023486 | NEQA6953388 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-15 20:09:07 |
| 2 | DFG-00282 | DFC-00225 | DPM1052510023062 | NJAA11479023 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-15 20:09:35 |
| 3 | DFG-00282 | DFC-00226 | DPM1052510023429 | NEQA6950788 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-15 20:09:58 |
| 4 | DFG-00282 | DFC-00227 | DPM1052510024488 | NJAA11458460 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-15 20:10:22 |
| 5 | DFG-00282 | DFC-00228 | DPM1052510023616 | NEQA6953489 | AMI | 1PH | Program Issue | Factory Setting | Disable optical | Reprogram & reverify meter | closed | medium | 2025-12-15 20:10:51 |
| 6 | DFG-00282 | DFC-00229 | DPM1052510023115 | NEQA6950232 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:11:31 |
| 7 | DFG-00282 | DFC-00230 | DPM1052510023396 | NEQA6946969 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:11:55 |
| 8 | DFG-00282 | DFC-00231 | DPM1052510023513 | NEQA6947251 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:12:19 |
| 9 | DFG-00282 | DFC-00232 | DPM1052510022918 | NJAA11480288 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:12:45 |
| 10 | DFG-00282 | DFC-00233 | DPM1052510023787 | NEQA6953476 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:13:16 |
| 11 | DFG-00282 | DFC-00234 | DPM1052510023743 | NJAA11472020 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:13:44 |
| 12 | DFG-00282 | DFC-00235 | DPM1052510023496 | NEQA6947155 | AMI | 1PH | Program Issue | Factory Setting | Shakehand | Reprogram & reverify meter | closed | medium | 2025-12-15 20:14:08 |
| 13 | DFG-00282 | DFC-00236 | DPM1052510023382 | NEQA6948037 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-15 20:15:13 |
| 14 | DFG-00282 | DFC-00237 | DPM1052510023648 | NEQA6950362 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-15 20:15:46 |
| 15 | DFG-00282 | DFC-00238 | DPM1052510022972 | NJAA11483321 | AMI | 1PH | Program Issue | Factory Setting | 0 | - | closed | medium | 2025-12-15 20:16:05 |
| 16 | DFG-00282 | DFC-00239 | DPM1052510022814 | NJAA11497037 | AMI | 1PH | Program Issue | Date & Time | Lambat 2 minit | SET DATE N TIME | closed | medium | 2025-12-15 20:17:50 |
| 17 | DFG-00282 | DFC-00240 | DPM1052510024008 | `NEQA6950651 | AMI | 1PH | Program Issue | Date & Time | Cepat 4 minit | SET DATE N TIME | closed | medium | 2025-12-15 20:18:40 |
| 18 | DFG-00282 | DFC-00241 | DPM1052510024034 | NJAA11473384 | AMI | 1PH | Program Issue | Date & Time | Lambat 2 minit | SET DATE N TIME | closed | medium | 2025-12-15 20:19:21 |
| 19 | DFG-00282 | DFC-00242 | DPM1052510024737 | NEQA6947762 | AMI | 1PH | Program Issue | Date & Time | Cepat 3 minit | REPLACE METER | closed | medium | 2025-12-15 20:20:00 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00281 | DFC-00199 | DPM1052510021512 | NJAA11477702 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:26:06 |
| 2 | DFG-00281 | DFC-00200 | DPM1052510021476 | NJAA11478259 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:26:43 |
| 3 | DFG-00281 | DFC-00201 | DPM1052510021118 | NEQA6947974 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:27:45 |
| 4 | DFG-00281 | DFC-00202 | DPM1052510021610 | NJAA11477951 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:28:05 |
| 5 | DFG-00281 | DFC-00203 | DPM1052510021709 | NJAA11500134 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:28:33 |
| 6 | DFG-00281 | DFC-00204 | DPM1052510021579 | NJAA11501771 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 11:29:04 |
| 7 | DFG-00281 | DFC-00205 | DPM1052510021652 | NJAA11499845 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-13 11:32:54 |
| 8 | DFG-00281 | DFC-00206 | DPM1052510021443 | NJAA11474748 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-13 11:33:17 |
| 9 | DFG-00281 | DFC-00207 | DPM1052510021148 | NEQA6947940 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-13 11:33:49 |
| 10 | DFG-00281 | DFC-00208 | DPM1052510020883 | NJAA11486320 | AMI | 1PH | Program Issue | Factory Setting | verify version | REPROGRAM | closed | medium | 2025-12-13 11:34:21 |
| 11 | DFG-00281 | DFC-00209 | DPM1052510020928 | NJAA11475483 | AMI | 1PH | Program Issue | Factory Setting | 0 | REPROGRAM | closed | medium | 2025-12-13 11:34:50 |
| 12 | DFG-00281 | DFC-00210 | DPM1052510020947 | NJAA11487869 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-12-13 11:35:23 |
| 13 | DFG-00281 | DFC-00212 | DPM1052510021792 | NJAA11497115 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-13 11:36:19 |
| 14 | DFG-00281 | DFC-00213 | DPM1052510022087 | NJAA11507820 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 16:04:08 |
| 15 | DFG-00281 | DFC-00214 | DPM1052510022627 | NJAA11501228 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 16:04:45 |
| 16 | DFG-00281 | DFC-00215 | DPM1052510022501 | NJAA11472032 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 16:05:05 |
| 17 | DFG-00281 | DFC-00216 | DPM1052510022415 | NEQA6948675 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 16:05:41 |
| 18 | DFG-00281 | DFC-00217 | DPM1052510021900 | NJAA11471573 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-13 16:06:13 |
| 19 | DFG-00281 | DFC-00218 | DPM1052510022178 | NJAA11470366 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-13 16:06:49 |
| 20 | DFG-00281 | DFC-00219 | DPM1052510021887 | NJAA11480630 | AMI | 1PH | Program Issue | Factory Setting | Read register | REDO FACTORY SETTING | cloased | medium | 2025-12-13 16:07:24 |
| 21 | DFG-00281 | DFC-00220 | DPM1052510022696 | NJAA11476941 | AMI | 1PH | Display Alarm | Battery | BATTERY PORT/BOARD PROBLEM | REPLACE METER | closed | medium | 2025-12-13 16:07:55 |
| 22 | DFG-00281 | DFC-00221 | DPM1052510022187 | NJAA11474607 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-13 16:08:32 |
| 23 | DFG-00281 | DFC-00222 | DPM1052510022043 | NJAA11479221 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-13 16:08:57 |
| 24 | DFG-00281 | DFC-00223 | DPM1052510022540 | NJAA11473871 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-13 16:09:24 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00280 | DFC-00336 | DPM1052510021148 | NEQA6947940 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-31 17:52:33 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00279 | DFC-00185 | DPM1052510020248 | NJAA11476675 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:34:57 |
| 2 | DFG-00279 | DFC-00186 | DPM1052510020206 | NJAA11496983 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:35:21 |
| 3 | DFG-00279 | DFC-00187 | DPM1052510020025 | NJAA11486395 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:35:46 |
| 4 | DFG-00279 | DFC-00188 | DPM1052510020170 | NJAA11473562 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:36:10 |
| 5 | DFG-00279 | DFC-00189 | DPM1052510020557 | NJAA11457477 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:36:31 |
| 6 | DFG-00279 | DFC-00190 | DPM1052510020105 | NJAA11497493 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:36:58 |
| 7 | DFG-00279 | DFC-00191 | DPM1052510020561 | NJAA11474184 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-11 17:37:27 |
| 8 | DFG-00279 | DFC-00192 | DPM1052510020713 | NJAA11469805 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-11 17:38:14 |
| 9 | DFG-00279 | DFC-00193 | DPM1052510020539 | NJAA11458016 | AMI | 1PH | Program Issue | Factory Setting | Read rated voltage | REDO FACTORY SETTING | closed | medium | 2025-12-11 17:39:20 |
| 10 | DFG-00279 | DFC-00194 | DPM1052510020373 | NJAA11478955 | AMI | 1PH | Program Issue | Factory Setting | Clear event energy | - | closed | medium | 2025-12-11 17:39:57 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00278 | DFC-00156 | DPM1052510017943 | NJAA11484897 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 14:28:58 |
| 2 | DFG-00278 | DFC-00157 | DPM1052510017819 | NJAA11477442 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 14:29:22 |
| 3 | DFG-00278 | DFC-00158 | DPM1052510018912 | NJAA11484840 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 14:30:02 |
| 4 | DFG-00278 | DFC-00159 | DPM1052510018521 | NJAA11501307 | AMI | 3PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 14:30:28 |
| 5 | DFG-00278 | DFC-00160 | DPM1052510017652 | NJAA11474646 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 14:31:39 |
| 6 | DFG-00278 | DFC-00161 | DPM1052510017753 | NJAA11480602 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 14:32:31 |
| 7 | DFG-00278 | DFC-00162 | DPM1052510018821 | NJAA11469591 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 14:32:59 |
| 8 | DFG-00278 | DFC-00163 | DPM1052510017355 | NJAA11476142 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 14:33:29 |
| 9 | DFG-00278 | DFC-00164 | DPM1052510018807 | NJAA11472453 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-10 14:34:27 |
| 10 | DFG-00278 | DFC-00165 | DPM1052510018861 | NJAA11457559 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-10 14:34:53 |
| 11 | DFG-00278 | DFC-00166 | DPM1052510018602 | NJAA11484861 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER 999925380146 | closed | high | 2025-12-10 14:35:33 |
| 12 | DFG-00278 | DFC-00169 | DPM1052510018122 | NJAA11478990 | AMI | 1PH | Display Alarm | Temper | SIGN WARNING | REPLACE METER 999925380134 | closed | medium | 2025-12-10 14:42:55 |
| 13 | DFG-00278 | DFC-00170 | DPM1052510017325 | NJAA11487859 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ADA BENDASING | REPLACE METER 999925380151 | closed | medium | 2025-12-10 14:44:59 |
| 14 | DFG-00278 | DFC-00171 | DPM1052510018817 | NJAA11485347 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ADA BENDASING | REPLACE METER | closed | medium | 2025-12-10 14:45:35 |
| 15 | DFG-00278 | DFC-00172 | DPM1052510017020 | NJAA11501806 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-12-10 14:46:14 |
| 16 | DFG-00278 | DFC-00173 | DPM1052510018503 | NJAA11458243 | AMI | 1PH | Physical Damage | Button | 0 | REPLACE METER | closed | medium | 2025-12-10 14:47:27 |
| 17 | DFG-00278 | DFC-00174 | DPM1052510019827 | NJAA11457454 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 19:06:38 |
| 18 | DFG-00278 | DFC-00175 | DPM1052510019564 | NJAA11475578 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 19:07:01 |
| 19 | DFG-00278 | DFC-00176 | DPM1052510019529 | NJAA11456387 | AMI | 1PH | Program Issue | Factory Setting | disable optical | Reprogram & reverify meter | closed | medium | 2025-12-10 19:07:27 |
| 20 | DFG-00278 | DFC-00177 | DPM1052510019896 | NJAA11508179 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 19:08:33 |
| 21 | DFG-00278 | DFC-00178 | DPM1052510019725 | NJAA11459296 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 19:09:15 |
| 22 | DFG-00278 | DFC-00179 | DPM1052510019380 | NJAA11471583 | AMI | 1PH | Program Issue | Factory Setting | shakehand | Reprogram & reverify meter | closed | medium | 2025-12-10 19:10:08 |
| 23 | DFG-00278 | DFC-00181 | DPM1052510019019 | NJAA11501400 | AMI | 1PH | Physical Damage | LCD Blank | LCD BLANK | REPLACE METER | closed | medium | 2025-12-10 19:11:49 |
| 24 | DFG-00278 | DFC-00182 | DPM1052510019253 | NJAA11472137 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-10 19:12:28 |
| 25 | DFG-00278 | DFC-00183 | DPM1052510019816 | NJAA11459882 | AMI | 1PH | Display Alarm | Terminal Cover | TERMINAL COVER BUTTON DEFECT | REPLACE METER 999925380158 | closed | medium | 2025-12-10 19:13:15 |
| 26 | DFG-00278 | DFC-00184 | DPM1052510019170 | NJAA11486495 | AMI | 1PH | Display Alarm | Terminal Cover | TERMINAL COVER BUTTON DEFECT | REPLACE METER 999925380149 | closed | medium | 2025-12-10 19:13:39 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00277 | DFC-00132 | DPM1052510016894 | NJAA11469921 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:43:25 |
| 2 | DFG-00277 | DFC-00133 | DPM1052510016924 | NJAA11478899 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:43:52 |
| 3 | DFG-00277 | DFC-00134 | DPM1052510016930 | NJAA11474198 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:44:19 |
| 4 | DFG-00277 | DFC-00135 | DPM1052510016489 | NJAA11475682 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:44:43 |
| 5 | DFG-00277 | DFC-00136 | DPM1052510016416 | NJAA11475137 | AMI | 1PH | Physical Damage | Scratch | 0 | REPLACE METER | closed | medium | 2025-12-09 08:47:02 |
| 6 | DFG-00277 | DFC-00137 | DPM1052510016183 | NJAA11473035 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:47:37 |
| 7 | DFG-00277 | DFC-00138 | DPM1052510016022 | NJAA11502651 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:48:20 |
| 8 | DFG-00277 | DFC-00139 | DPM1052510014955 | NJAA11480014 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:48:46 |
| 9 | DFG-00277 | DFC-00140 | DPM1052510016199 | NJAA11471206 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:49:10 |
| 10 | DFG-00277 | DFC-00141 | DPM1052510016198 | NJAA11499888 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:49:33 |
| 11 | DFG-00277 | DFC-00142 | DPM1052510016877 | NJAA11500224 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:50:15 |
| 12 | DFG-00277 | DFC-00143 | DPM1052510016805 | NJAA11471839 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:50:41 |
| 13 | DFG-00277 | DFC-00144 | DPM1052510016683 | NJAA11469470 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:51:13 |
| 14 | DFG-00277 | DFC-00145 | DPM1052510016588 | NJAA11499601 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:51:42 |
| 15 | DFG-00277 | DFC-00146 | DPM1052510016095 | NJAA11471853 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:52:10 |
| 16 | DFG-00277 | DFC-00147 | DPM1052510014341 | NJAA11510757 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:54:21 |
| 17 | DFG-00277 | DFC-00148 | DPM1052510014586 | NJAA11476795 | AMI | 1PH | Program Issue | Factory Setting | - | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:55:24 |
| 18 | DFG-00277 | DFC-00149 | DPM1052510014822 | NJAA11510705 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:55:48 |
| 19 | DFG-00277 | DFC-00150 | DPM1052510014074 | NJAA11478258 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:56:17 |
| 20 | DFG-00277 | DFC-00151 | DPM1052510014043 | NJAA11476662 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-09 08:56:52 |
| 21 | DFG-00277 | DFC-00152 | DPM1052510014497 | NJAA11505392 | AMI | 1PH | Program Issue | Date & Time | DRIFT | REPLACE METER | closed | medium | 2025-12-09 08:57:20 |
| 22 | DFG-00277 | DFC-00153 | DPM1052510014585 | NJAA11507588 | AMI | 1PH | Program Issue | Date & Time | DRIFT | REPLACE METER | closed | medium | 2025-12-09 08:57:48 |
| 23 | DFG-00277 | DFC-00154 | DPM1052510015444 | NJAA11497930 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-12-09 11:01:12 |
| 24 | DFG-00277 | DFC-00155 | DPM1052510015005 | NJAA11499191 | AMI | 1PH | Display Alarm | Temper | SIGN WARNING | REPLACE METER 999925380139 | closed | medium | 2025-12-09 11:01:39 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00276 | DFC-00120 | DPM1052510013019 | NJAA11477204 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 09:59:29 |
| 2 | DFG-00276 | DFC-00121 | DPM1052510013806 | NJAA11472244 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 09:59:53 |
| 3 | DFG-00276 | DFC-00122 | DPM1052510013741 | NJAA11469721 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 10:00:15 |
| 4 | DFG-00276 | DFC-00123 | DPM1052510013608 | NJAA11480660 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 10:00:42 |
| 5 | DFG-00276 | DFC-00124 | DPM1052510012465 | NJAA11502043 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | - | closed | medium | 2025-12-06 10:01:08 |
| 6 | DFG-00276 | DFC-00125 | DPM1052510012089 | NJAA11488765 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 10:01:34 |
| 7 | DFG-00276 | DFC-00126 | DPM1052510012058 | NJAA11510394 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-06 10:01:57 |
| 8 | DFG-00276 | DFC-00127 | DPM1052510012794 | NJAA11501937 | AMI | 1PH | Program Issue | Date & Time | 0 | REPLACE METER | closed | medium | 2025-12-06 10:02:30 |
| 9 | DFG-00276 | DFC-00128 | DPM1052510012486 | NJAA11505577 | AMI | 1PH | Physical Damage | Scratch | 0 | PASS | closed | medium | 2025-12-06 10:03:05 |
| 10 | DFG-00276 | DFC-00129 | DPM1052510012176 | NJAA11479737 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-06 10:03:31 |
| 11 | DFG-00276 | DFC-00130 | DPM1052510012975 | NJAA11471405 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-06 10:03:58 |
| 12 | DFG-00276 | DFC-00131 | DPM1052510012966 | NJAA11482223 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-06 10:04:28 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00275 | DFC-00106 | DPM1052510009000 | NJAA11498644 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:09:57 |
| 2 | DFG-00275 | DFC-00107 | DPM1052510008627 | NJAA11507672 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:10:30 |
| 3 | DFG-00275 | DFC-00108 | DPM1052510008585 | NJAA11470039 | AMI | 1PH | Program Issue | Date & Time | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:10:56 |
| 4 | DFG-00275 | DFC-00109 | DPM1052510011534 | NJAA11498940 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:11:37 |
| 5 | DFG-00275 | DFC-00110 | DPM1052510011882 | NJAA11480144 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:12:06 |
| 6 | DFG-00275 | DFC-00111 | DPM1052510011888 | NJAA11479549 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:12:32 |
| 7 | DFG-00275 | DFC-00112 | DPM1052510011364 | NJAA11508784 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-12-05 11:13:07 |
| 8 | DFG-00275 | DFC-00113 | DPM1052510011908 | NJAA11506942 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:13:37 |
| 9 | DFG-00275 | DFC-00114 | DPM1052510011083 | NJAA11500329 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-12-05 11:14:14 |
| 10 | DFG-00275 | DFC-00115 | DPM1052510011284 | NJAA11470479 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:14:48 |
| 11 | DFG-00275 | DFC-00116 | DPM1052510010987 | NJAA11503823 | AMI | 1PH | Program Issue | Factory Setting | FAIL FACTORY SETTING | REDO FACTORY SETTING | closed | medium | 2025-12-05 11:15:28 |
| 12 | DFG-00275 | DFC-00117 | DPM1052510010421 | NJAA11487951 | AMI | 1PH | Program Issue | Factory Setting | 0 | REPLACE METER | closed | medium | 2025-12-05 11:15:56 |
| 13 | DFG-00275 | DFC-00119 | DPM1052510010422 | NJAA11502401 | AMI | 1PH | Program Issue | Date & Time | 0 | REPLACE METER | closed | medium | 2025-12-05 11:17:04 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00274 | DFC-00104 | DPM1052510009458 | NJAA11470048 | AMI | 1PH | Physical Damage | LCD Crack | 0 | REPLACE METER | closed | medium | 2025-12-04 17:44:35 |
| 2 | DFG-00274 | DFC-00105 | DPM1052510008816 | NJAA11477445 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REPLACE METER | closed | medium | 2025-12-04 17:45:04 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00273 | DFC-00099 | DPM1052510006233 | NJAA11501518 | AMI | 1PH | Physical Damage | Scratch | 0 | PASS | closed | medium | 2025-12-03 15:44:42 |
| 2 | DFG-00273 | DFC-00100 | DPM1052510006279 | NJAA11470061 | AMI | 1PH | Physical Damage | Scratch | 0 | PASS | closed | medium | 2025-12-03 15:45:24 |
| 3 | DFG-00273 | DFC-00101 | DPM1052510006787 | NJAA11478582 | AMI | 1PH | Program Issue | Date & Time | 0 | REPLACE METER | closed | medium | 2025-12-03 15:45:53 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00272 | DFC-00097 | DPM1052510005581 | NJAA11487136 | AMI | 1PH | Physical Damage | LCD Crack | 0 | REPLACE METER | closed | medium | 2025-12-02 11:09:27 |
| 2 | DFG-00272 | DFC-00098 | DPM1052510004735 | NJAA11503674 | AMI | 1PH | Physical Damage | Button | 0 | REPLACE METER | closed | medium | 2025-12-02 11:09:55 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00271 | DFC-00095 | DPM1052510004403 | NJAA11505387 | AMI | 1PH | Physical Damage | Scratch | SCRATCH | REPLACE METER | closed | medium | 2025-12-01 11:01:21 |
| 2 | DFG-00271 | DFC-00096 | DPM1052510004305 | NJAA11482415 | AMI | 1PH | Physical Damage | Scratch | SCRATCH | REPLACE METER | closed | medium | 2025-12-01 11:01:55 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00270 | DFC-00092 | DPM1052510001240 | NJAA11506714 | AMI | 1PH | Physical Damage | Button | BUTTON POPUP | REPLACE METER | closed | medium | 2025-11-28 11:18:11 |
| 2 | DFG-00270 | DFC-00093 | DPM1052510000844 | NJAA11488364 | AMI | 1PH | Display Alarm | Temper | 0 | REPLACE METER | closed | medium | 2025-11-28 11:19:15 |
| 3 | DFG-00270 | DFC-00094 | DPM1052510001799 | NEQA6924006 | AMI | 1PH | Physical Damage | Scratch | SCRATCH | REPLACE METER | closed | medium | 2025-11-28 11:19:49 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00269 | DFC-00091 | DPM1052509039234 | NEQA6731352 | AMI | 1PH | Physical Damage | Nameplate | ada plastik | REPLACE METER | closed | medium | 2025-11-25 08:36:08 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00268 | DFC-00089 | DPM1052509024049 | NEQA6751884 | AMI | 1PH | Physical Damage | LCD Crack | LCD SEGMENT PROBLEM | REPLACE METER | closed | medium | 2025-11-24 09:14:14 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00267 | DFC-00088 | DPM1052509038017 | NEQA6727050 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ada plastik dekat lcd | REPLACE METER | closed | medium | 2025-11-21 09:04:53 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00266 | DFC-00087 | DPM1052509037339 | NEQA6730967 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ADA BENDASING | REPLACE METER | closed | medium | 2025-11-20 09:43:16 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00265 | DFC-00085 | DPM1052509036611 | NEQA6726978 | AMI | 1PH | Program Issue | Date & Time | 0 | SET DATE N TIME | closed | medium | 2025-11-19 08:37:26 |
| 2 | DFG-00265 | DFC-00086 | DPM1052509036241 | NEQA6745897 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-19 08:38:04 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00264 | DFC-00083 | DPM1052509032276 | NEQA6730310 | AMI | 1PH | Physical Damage | Button | button stuck | REPLACE METER | closed | medium | 2025-11-18 15:44:42 |
| 2 | DFG-00264 | DFC-00084 | DPM1052509035344 | NEQA6733354 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ADA BENDASING | REPLACE METER | closed | medium | 2025-11-18 15:45:18 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00263 | DFC-00071 | DPM1052509032932 | NEQA6732074 | AMI | 1PH | Physical Damage | Terminal Block | TERMINAL COVER BUTTON DEFECT | REPLACE METER | closed | medium | 2025-11-17 15:13:05 |
| 2 | DFG-00263 | DFC-00072 | DPM1052509034876 | NEQA6731002 | AMI | 1PH | Physical Damage | LCD Blank | LCD PROBLEM | REPLACE METER | closed | medium | 2025-11-17 15:14:34 |
| 3 | DFG-00263 | DFC-00073 | DPM1052509034036 | NEQA6731173 | AMI | 1PH | Physical Damage | Button | terjojol | REPLACE METER | closed | medium | 2025-11-17 15:15:21 |
| 4 | DFG-00263 | DFC-00074 | DPM1052509033802 | NEQA6743715 | AMI | 1PH | Physical Damage | Terminal Block | no thread | INSERT THREAD | closed | medium | 2025-11-17 15:16:19 |
| 5 | DFG-00263 | DFC-00075 | DPM1052509034455 | NEQA6730076 | AMI | 1PH | Physical Damage | Terminal Block | no thread | INSERT THREAD | closed | medium | 2025-11-17 15:17:20 |
| 6 | DFG-00263 | DFC-00076 | DPM1052509032797 | NEQA6726019 | AMI | 1PH | Program Issue | Date & Time | 0 | SET DATE N TIME | closed | medium | 2025-11-17 15:18:00 |
| 7 | DFG-00263 | DFC-00077 | DPM1052509033978 | NEQA6726509 | AMI | 1PH | Program Issue | Date & Time | 0 | REPLACE | closed | medium | 2025-11-17 15:18:30 |
| 8 | DFG-00263 | DFC-00078 | DPM1052509034649 | NEQA6737452 | AMI | 1PH | Physical Damage | Scratch | o | PASS | closed | medium | 2025-11-17 15:19:27 |
| 9 | DFG-00263 | DFC-00079 | DPM1052509032701 | NEQA6743055 | AMI | 1PH | Physical Damage | Scratch | 0 | PASS | closed | medium | 2025-11-17 15:20:14 |
| 10 | DFG-00263 | DFC-00082 | DPM1052509033057 | NEQA6730323 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | 0 | REMOVE DIRT | closed | medium | 2025-11-17 15:22:53 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00262 | DFC-00063 | DPM1052509031155 | NEQA6743192 | AMI | 1PH | Program Issue | Date & Time | 0 | SET DATE N TIME | closed | medium | 2025-11-13 09:09:06 |
| 2 | DFG-00262 | DFC-00064 | DPM1052509030856 | NEQA6738792 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-13 09:09:43 |
| 3 | DFG-00262 | DFC-00065 | DPM1052509030419 | NEQA6730033 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-11-13 09:11:21 |
| 4 | DFG-00262 | DFC-00066 | DPM1052509030464 | NEQA6745890 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | PASS | closed | medium | 2025-11-13 09:11:55 |
| 5 | DFG-00262 | DFC-00067 | DPM1052509030234 | NEQA6736981 | AMI | 1PH | Physical Damage | Ring | 0 | PASS | closed | medium | 2025-11-13 09:12:35 |
| 6 | DFG-00262 | DFC-00068 | DPM1052509031354 | NEQA6738964 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-11-13 09:13:21 |
| 7 | DFG-00262 | DFC-00069 | DPM1052509031416 | NEQA6731268 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-11-13 09:14:01 |
| 8 | DFG-00262 | DFC-00070 | DPM1052509031338 | NEQA6736467 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-13 09:14:56 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00261 | DFC-00043 | DPM1052509030203 | NEQA6736653 | AMI | 1PH | Program Issue | Date & Time | DATE | REPLACE METER | closed | medium | 2025-11-12 09:24:02 |
| 2 | DFG-00261 | DFC-00057 | DPM1052509030630 | NEQA6737613 | AMI | 1PH | Physical Damage | Scratch | 00 | PASS | closed | medium | 2025-11-12 09:25:50 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00260 | DFC-00037 | DPM1052509030019 | NEQA6726938 | AMI | 1PH | Physical Damage | Nameplate | NAMEPLATE NOT SLOT IN | REPLACE METER | closed | medium | 2025-11-11 08:38:55 |
| 2 | DFG-00260 | DFC-00038 | DPM1052509029711 | NEQA6727017 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-11 08:39:48 |
| 3 | DFG-00260 | DFC-00039 | DPM1052509029598 | NEQA6730694 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ADA BENDASING | REPLACE METER | closed | medium | 2025-11-11 08:41:18 |
| 4 | DFG-00260 | DFC-00040 | DPM1052509029428 | NEQA6731029 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-11-11 08:42:09 |
| 5 | DFG-00260 | DFC-00041 | DPM1052509029433 | NEQA6730607 | AMI | 1PH | Physical Damage | Nameplate | tak slot in | REPLACE METER | closed | medium | 2025-11-11 08:43:17 |
| 6 | DFG-00260 | DFC-00042 | DPM1052509029680 | NEQA6739304 | AMI | 1PH | Physical Damage | Scratch | fizikal module cover | REPLACE METER | closed | medium | 2025-11-11 08:45:32 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00259 | DFC-00036 | DPM1052509028846 | NEQA6737169 | AMI | 1PH | Physical Damage | Nameplate | nameplate dekat lcd | REPLACE METER | closed | medium | 2025-11-10 08:56:21 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00258 | DFC-00032 | DPM1052509027016 | NEQA6750441 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-08 09:38:18 |
| 2 | DFG-00258 | DFC-00033 | DPM1052509027085 | NEQA6752589 | AMI | 1PH | Physical Damage | Bonding | 0 | PASS | closed | medium | 2025-11-08 09:39:00 |
| 3 | DFG-00258 | DFC-00034 | DPM1052509027039 | NEQA6750883 | AMI | 1PH | Physical Damage | Bonding | 0 | PASS | closed | medium | 2025-11-08 09:39:30 |
| 4 | DFG-00258 | DFC-00035 | DPM1052509025998 | NEQA6751796 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-08 09:40:02 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00257 | DFC-00027 | DPM1052509024972 | NEQA6740642 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-07 11:03:06 |
| 2 | DFG-00257 | DFC-00028 | DPM1052509024885 | NEQA6750615 | AMI | 1PH | Physical Damage | Button | BUTTON PROBLEM | REPLACE METER | closed | medium | 2025-11-07 11:04:32 |
| 3 | DFG-00257 | DFC-00029 | DPM1052509025646 | NEQA6742383 | AMI | 1PH | Program Issue | Date & Time | 0 | SET DATE N TIME | closed | medium | 2025-11-07 11:05:16 |
| 4 | DFG-00257 | DFC-00030 | DPM1052509025575 | NEQA6754131 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-07 11:05:51 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00256 | DFC-00025 | DPM1052509021033 | NEQA6735648 | AMI | 1PH | Physical Damage | Scratch | lcd SCRATCH | REPLACE METER | closed | medium | 2025-11-06 14:28:30 |
| 2 | DFG-00256 | DFC-00026 | DPM1052509021907 | NEQA6728219 | AMI | 1PH | Physical Damage | Missing Modul Thread | MODUL NO THREAD | REPLACE METER | closed | medium | 2025-11-06 14:29:15 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00255 | DFC-00014 | DPM1052509019606 | NEQA6728323 | AMI | 1PH | Physical Damage | Missing Modul Thread | modul thread | insert thread at modul | closed | medium | 2025-11-04 09:11:55 |
| 2 | DFG-00255 | DFC-00015 | DPM1052509019104 | NEQA6734531 | AMI | 1PH | Program Issue | Date & Time | 0 | SET DATE N TIME | closed | medium | 2025-11-04 09:14:47 |
| 3 | DFG-00255 | DFC-00016 | DPM1052509019603 | NEQA6729039 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-04 09:16:46 |
| 4 | DFG-00255 | DFC-00017 | DPM1052509019584 | NEQA6761096 | AMI | 1PH | Program Issue | Date & Time | DATE N TIME DRIFT | REPLACE METER | closed | medium | 2025-11-04 09:17:52 |
| 5 | DFG-00255 | DFC-00018 | DPM1052509020382 | NEQA6765050 | AMI | 1PH | Display Alarm | Terminal Cover | 0 | REPLACE METER | closed | medium | 2025-11-04 09:19:31 |
| 6 | DFG-00255 | DFC-00019 | DPM1052509020563 | NEQA6752187 | AMI | 1PH | Display Alarm | Temper | TEMPER ALARM | REPLACE METER | closed | medium | 2025-11-04 09:20:50 |
| 7 | DFG-00255 | DFC-00020 | DPM1052509019790 | NEQA6735807 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-04 16:28:27 |
| 8 | DFG-00255 | DFC-00021 | DPM1052509019851 | NEQA6732117 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-04 16:29:19 |
| 9 | DFG-00255 | DFC-00022 | DPM1052509019988 | NEQA6740601 | AMI | 1PH | Physical Damage | Bonding | meter renggang | Replace Meter | closed | medium | 2025-11-04 16:29:57 |
| 10 | DFG-00255 | DFC-00023 | DPM1052509019916 | NEQA6732266 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-04 16:30:29 |
| 11 | DFG-00255 | DFC-00024 | DPM1052509019996 | NEQA6740826 | AMI | 1PH | Physical Damage | Bonding | BONDING PROBLEM | REPLACE METER | closed | medium | 2025-11-04 16:31:08 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00254 | DFC-00006 | DPM1052509018174 | NEQA6760160 | AMI | 1PH | Physical Damage | Dirty/Dust/Foregn object | ada bendasing dekat lcd | REPLACE METER | closed | medium | 2025-11-03 14:53:02 |
| 2 | DFG-00254 | DFC-00007 | DPM1052509018687 | NEQA6754210 | AMI | 1PH | - | Terminal Cover | Terminal cover alarm | REPLACE METER | closed | medium | 2025-11-03 14:55:34 |
| 3 | DFG-00254 | DFC-00008 | DPM1052509017504 | NEQA6757155 | AMI | 1PH | Program Issue | Date & Time | date and time | SET DATE N TIME | closed | medium | 2025-11-03 14:56:29 |
| 4 | DFG-00254 | DFC-00009 | DPM1052509017187 | NEQA6761437 | AMI | 1PH | Program Issue | Date & Time | date and time | SET DATE N TIME | closed | medium | 2025-11-03 14:57:36 |
| 5 | DFG-00254 | DFC-00011 | DPM1052509017869 | NEQA6748975 | AMI | 1PH | Program Issue | Date & Time | date and time | SET DATE N TIME | closed | medium | 2025-11-03 15:00:04 |
| 6 | DFG-00254 | DFC-00012 | DPM1052509018763 | NEQA6762099 | AMI | 1PH | Other | - | fizikal meter | REPLACE METER | closed | medium | 2025-11-03 15:01:56 |
| 7 | DFG-00254 | DFC-00013 | DPM1052509017756 | NEQA6754129 | AMI | 1PH | Program Issue | Date & Time | date and time | SET DATE N TIME | closed | medium | 2025-11-03 15:03:21 |
| # | Report Number | Ticket | Meter S/N | OSDI S/N | Model | Type | Category | Sub-Category | Description | Action Taken | Status | Priority | Created At |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | DFG-00253 | DFC-00001 | DPM1052509000183 | - | AMI | 1PH | Other | - | DATE N TIME | REPLACE METER | closed | medium | 2025-11-03 10:10:15 |
| 2 | DFG-00253 | DFC-00002 | DPM1052509001184 | - | AMI | 1PH | Other | - | TERMINAL COVER STATUS | - | closed | medium | 2025-11-03 10:31:01 |
| 3 | DFG-00253 | DFC-00003 | DPM1052509001296 | - | AMI | 1PH | Program Issue | Date & Time | READ DATE N TIME | REPLACE METER | closed | medium | 2025-11-03 10:34:48 |
| 4 | DFG-00253 | DFC-00004 | DPM1052509001455 | - | AMI | 1PH | Physical Damage | 8 Segment Missing | LCD SEGMENT PROBLEM | jbrjgjtjg | closed | medium | 2025-11-03 10:35:43 |
| 5 | DFG-00253 | DFC-00005 | DPM1052509001772 | - | AMI | 1PH | Other | - | foreign object | REPLACE METER | closed | medium | 2025-11-03 10:46:16 |